A simple rule of thumb: plan for 8–12 m² per full-time employee in Cairo. That covers workstations, meeting rooms, kitchen, reception, and circulation. But the useful version of this question depends on your role mix, meeting density, and hybrid ratio. This guide gives you the sizing table PLACES uses with real clients.
Per full-time employee, all-in
Below 8 = your team feels cramped and starts leaving. Above 14 = you're overpaying rent for space that doesn't earn its keep.
The formula
For a Cairo office in 2026, calculate total space needed as:
(workstation seats × m² per seat) +
meeting room space +
shared amenities +
15–20% circulation
The variables depend on your role mix and how open your layout is. Let's break each one down.
Workstation space per seat
In Cairo offices, per-seat allocations typically fall into three tiers:
| Layout type | m² per seat | Best for |
|---|---|---|
| Dense open-plan (bench desks) | 4 – 5 | Tech, call centers, junior teams |
| Standard open-plan (individual desks) | 5.5 – 7 | Most corporate offices, professional services |
| Cubicles / semi-private | 7 – 9 | Financial services, government-adjacent |
| Private offices (mid-level) | 9 – 14 | Law firms, consulting partners |
| Corner offices (senior) | 18 – 30 | C-suite, senior partners |
These figures are for the workstation footprint plus immediately adjacent circulation — they don't include meeting rooms, kitchen, or reception, which come next.

Meeting rooms
The standard Cairo benchmark:
- 4-person huddle room — 8–10 m² each. Need 1 per 12–15 workstations.
- 6-person meeting room — 14–18 m² each. Need 1 per 25 workstations.
- 10-person conference room — 25–35 m² each. Need 1 for offices over 25 people.
- Boardroom — 40–60 m². Need 1 for offices with C-suite presence.
For a modern hybrid office where 60–70% of the team is in on any given day, you need MORE meeting rooms proportionally than the old benchmarks — because in-office days concentrate collaborative work, and video calls require enclosed spaces to avoid interrupting open-plan neighbors.
Shared amenities
A Cairo office typically needs:
- Reception — 8–20 m² depending on client-facing intensity. Law firms and consultancies budget more; back-office operations can skip a dedicated reception.
- Kitchen / pantry — 8–15 m² for teams up to 30, scaling to 20–30 m² for 30+ teams. Include space for a fridge, coffee setup, water dispenser, microwave, and 4–6 people to congregate.
- Storage / server room — 5–10 m² baseline, more if you have physical archives or on-premise servers.
- Break-out / lounge — 15–25 m² for teams that value informal collaboration space. Optional but increasingly expected by younger tenants.
- Restrooms. Buildings vary — some include shared floor restrooms in the common areas, some require you to build within your unit. Budget 3–5 m² per restroom, minimum 2 (one M, one F) for teams under 15.
Circulation
You can't use every square meter. Corridors, awkward corners, walkways to shared amenities — realistic circulation overhead is 15–20% of total floor area. Dense open-plan can hit 12%; heavily-partitioned layouts run 20–25%.
Worked example: a 30-person office
Let's size an office for a typical 30-person professional services firm in Cairo:
- 25 open-plan workstations × 6 m² = 150 m²
- 5 private offices × 12 m² = 60 m²
- 2 huddle rooms × 9 m² = 18 m²
- 1 meeting room × 16 m² = 16 m²
- 1 conference room × 30 m² = 30 m²
- Reception = 15 m²
- Kitchen = 14 m²
- Storage + server = 8 m²
- Break-out lounge = 18 m²
- Restrooms (built within unit) = 10 m²
Subtotal: 339 m². Add 18% circulation: ~400 m² total — or about 13 m² per person.
That's for a firm with a reasonable mix of privacy and open-plan. A tech company with the same headcount but fully open-plan and smaller private offices lands closer to ~280 m² (9 m² per person).
Adjusting for hybrid working
If your team is fully in-office five days a week, the tables above give you the right answer. If you're hybrid, you can reduce the workstation count while keeping meeting-room and amenity counts the same.
The common patterns:
- 1:1 hot-desking (100% seat ratio) — one seat per employee. What most Cairo offices still run.
- 0.8:1 ratio (80% seats) — for teams with 1–2 fixed remote days per week. Cuts space needs ~15%.
- 0.6:1 ratio (60% seats) — for aggressive hybrid models with 2–3 remote days average. Cuts space ~30%. Requires solid meeting-room booking systems and workstation reservation software.
A word of caution: aggressive hot-desking (below 0.7:1) works in tech companies where employees are used to no fixed desks. It usually doesn't work in Egyptian professional services firms where senior staff expect assigned space. Size for what your culture actually is, not what you wish it were.
What to do next
Once you have a rough total, cross-reference against Cairo rental prices by district to get an all-in budget. Then:
- Browse listings filtered to your size range — most Cairo units come in 80, 120, 150, 200, 300, and 500+ m² floor plates.
- Read our rent process guide for what to check on site visits.
- Talk to a PLACES advisor — send us your headcount and role mix and we'll build you a proper space plan.